ALBA Synchrotron
Technical and Safety reasons
As a general rule, experiments on BL09-MISTRAL have to be performed exclusively with samples and equipments described in proposals (academic, in-house, proprietary) and validated by ALBA Health and Safety Office.
What cannot be done at the BL for technical reasons:
- Spectroscopy at C-edge
- Magnetism experiments with continuous applied fields above ~20 Oe. At present we have not implemented a "high" field continuous operation but only pulsed fields.
What cannot be done at the BL for safety reasons:
- Any biological sample which requires safety level above 2.
- Radioactive compounds: Radioactive sources as defined in RD 35/2008 will not be accepted. Samples containing radioactive isotopes below these specific limits MUST be declared and acceptance will be studied case by case.
- Illegal substances and/or samples: (f.i. drugs, unregulated agricultural or food samples, etc.) unless it is explicitly proved that it is allowed by Spanish regulations.
- Nanoparticles: Powder samples with sub-micron grain sizes are considered herein. Measurement on nano size materials could be authorized when sample is properly filled in sealed confinement, firmly bonded to a substrate or incorporated to a biological sample in such a way that nanoparticles are firmly bonded to it. However, the manipulation on the beamline and/or related laboratory of loose powder is forbidden.
Disclaimer: This list is not comprehensive; it only indicates the experimental conditions and sample characteristics that could not be accepted due to technical and/or safety reasons. The acceptance of any materials (including equipment) is subjected to the availability of all required safety conditions and protective equipment.