ALBA Synchrotron
In-vacuum undulator (IVU21). The photon source of the XALOC beamline is an in-vacuum undulator placed in a medium straight section of the ALBA storage ring. The undulator is fully tunable within the useful energy range for Macromolecular Crystallography experiments (4.6 - 23 keV).
Parameters
Material | Sm5Co17 Pure Permanent Magnet |
Period | 21.6 mm |
Number of periods | 92 |
K at minimum gap (5.7 mm) | 1.7378 |
Photon source size (FWHM) | 309 x 18 µm2 (HxV) |
Photon source div. (FWHM) | 112 x 28-22 µrad2 (HxV) |